Multi-times foundry/casting mill using thermal analysis immersion thermocouple

Views : 993
Update time : 2017-01-26 09:38:03

Multi-times foundry/casting mill using thermal analysis immersion thermocouple

 
I Purpose and Working Principle of Fast Thermal Analysis Thermocouple:
Used for measuring the temperature of molten steel and high-temperature molten metal, fast thermal analysis thermocouple is reusable immersion thermocouple . Based on the thermoelectric effect of metals, it works according to the temperature difference between its two sides.
 
II Product Specifications and Performance Comparisons:
Name Model Type Permissible Deviation Recommended Temperature Max Temperature Response Time
Platinum-30% Rhodium/Platinum-6% Rhodium thermocouple  KB-602 B ±5 1500-1700 1800 4~6s
Platinum-10% Rhodium/Platinum thermocouple KS-602 S ±5 1500-1700 1800 4~6s
Platinum-13% Rhodium/Platinum thermocouple KR-602 R ±5 1500-1700 1800 4~6s
Tungsten 30%/ tungsten-rhenium 25% KW-602 W ±5 1500-1700 1800 4~6s
 
III Structure
Fast thermal analysis thermocouple is mainly composed of temperature measuring probe and a big paper tube. Positive wire and negative wire of the temperature measuring probe are welded to a compensating lead wire embedded in a support bracket covered by a small paper tube. The thermo wires are supported and protected by quartz. The temperature measuring probe is covered by a cap to protect from dregs. All the components are put into a thermocouple tip and are bonded by fire-resistant filler into a whole. Therefore, the fast thermocouple is for one-time use.
 
IV Usage
1, To select the appropriate length of protective paper tube and temperature measuring gun according to the object and scope of the measurement
2, Attach the fast thermocouple to the temperature measuring gun, make the pointer of the secondary instrument (or digital display) back to zero. Begin to measure.
3, It is recommended to insert the fast thermocouple in to the molten steel at the depth of 300-400mm. Do not touch the furnace wall or scum. Bring up the temperature measuring gun immediately after the secondary instrument get results. The soak time of fast thermocouple in molten steel should less than 5 seconds, otherwise the gun may be burned out.
4, Change the used thermocouple into a new one, and pause for a few minutes to get ready for the next measurement.
 
V Transport and Storage
Be careful when assembling and removing the parts. Keep dry in the transportation process. The products should be put into cases and stored at ware houses where the relative humidity is less than 80%. Keeps the air flowing. The air should not contain harmful gases which may corrode the product